Products Company Order News Technical



     
PRODUCTS / SPECIALTY CABLE / HYDROBLOC™ WATER-RESISTANT CABLE / Multi-Conductor Shielded
 
     
  HydroBloc™ Multi-Conductor Shielded  
         
   
  The Gepco® Brand HydroBloc™ multi-conductor shielded speaker and control cables are ideal for permanent installation in wet locations. The conductors consist of stranded or solid bare copper conductors that are insulated with a PVC insulation compound. For added noise rejection and suppression, the conductors are shielded with a durable 100% foil/Mylar® and tinned copper drain wire. The outer jacket is extruded from a low-friction PVC that is easy to install and pull through conduit. Gepco Brand shielded speaker and control cables are available in 18 through 22 AWG. With advanced water-blocked construction, the HydroBloc line utilizes a two-ply water-blocking tape and water-swellable fillers to prevent transverse and longitudinal water ingress.
 
FEATURES & BENEFITS
Advanced Water-Blocked Construction
Sunlight- and Moisture-Resistant Jacket
Cables Comply with TIA-455-82-B Water Penetration Test
Ripcord for Ease of Stripping Jacket
Bare Copper Conductors
Superior PVC Insulation
Foil Shield with Drain Wire
18 Through 22 AWG Versions
UL Rated
   
APPLICATIONS
In Wet Locations Inside Conduit
Indoor/Outdoor Use
Speaker Interconnections
General Purpose Audio
Communications & Power-Limited Circuits
 
         

 Mechanical Specifications (Series)

Part #

# of
Cond.

Nominal
OD

Conductor

Insulation/Color Code

Shield

Drain
Wire

Jacket
(Type, Colors)

UL
Type

Approx.
Weight

HBS2220

2

0.192“
(5.00 mm)

22 AWG
Solid BC

PVC, 0.010” (0.254 mm)/
Black, Red

100%
Foil

24 AWG
Solid TC

PVC, Gray

CM/CL3

22 lbs/Mft

(33 kg/km)

 22 AWG Solid x 2 HydroBloc™ CM/CL3 Water-Resistant Cable: Shielded

HBS222

2

0.202“
(5.13 mm)

22 AWG (7x30)
Stranded BC

PVC, 0.010” (0.254 mm)/
Black, Red

100%
Foil

24 AWG (7x32)
Stranded TC

PVC, Gray

CM/CL3

26 lbs/Mft

(40 kg/km)

 22 AWG Stranded x 2 HydroBloc™ CM/CL3 Water-Resistant Cable: Shielded

HBS202

2

0.220“
(5.59 mm)

20 AWG (7x28)
Stranded BC

PVC, 0.010” (0.254 mm)/
Black, Red

100%
Foil

22 AWG (7x30)
Stranded TC

PVC, Gray

CM/CL3

27 lbs/Mft

(40 kg/km)

 20 AWG Stranded x 2 HydroBloc™ CM/CL3 Water-Resistant Cable: Shielded

HBS182

2

0.236“
(5.99 mm)

18 AWG (7x26)
Stranded BC

PVC, 0.010” (0.254 mm)/
Black, Red

100%
Foil

22 AWG (7x30)
Stranded TC

PVC, Gray

CM/CL3

33 lbs/Mft

(50 kg/km)

 18 AWG Stranded x 2 HydroBloc™ CM/CL3 Water-Resistant Cable: Shielded

HBS186

6

0.302“
(7.67 mm)

18 AWG (7x26)
Stranded BC

PVC, 0.010” (0.254 mm)/
Black, Red, White, Green, Brown, Blue

100%
Foil

22 AWG (7x30)
Stranded TC

PVC, Gray

CM/CL3

67 lbs/Mft

(100 kg/km)

 18 AWG Stranded x 4 HydroBloc™ CM/CL3 Water-Resistant Cable: Shielded

 Electrical Specifications

 

Part #

Cond. DCR

Capacitance

 

HBS2220

16.5 Ω/Mft

49 pF/ft Between Conductors, 89 pF/ft Between One Conductor and Other Tied to Shield

 

HBS222

15.3 Ω/Mft

55 pF/ft Between Conductors, 99 pF/ft Between One Conductor and Other Tied to Shield

 

HBS202

10.1 Ω/Mft

61 pF/ft Between Conductors, 109 pF/ft Between One Conductor and Other Tied to Shield

 

HBS182/HBS186

6.4 Ω/Mft

70 pF/ft Between Conductors, 126 pF/ft Between One Conductor and Others Tied to Shield


   Back