Shielded, low-capacitance, twisted-pairs under a single round jacket. The 6100 series features an extra-thick, solid polyethylene dielectric to reduce the high frequency attenuation of the pairs. Overall foil shield with drain supplies RF protection in addition to the common-mode rejection provided by the twisted-pairs. Ideal for higher data rates, machine control, or extended distance runs where capacitance needs to be minimized.
FEATURES & BENEFITS
Low Capacitance
Polyethylene Dielectric
Overall Shield & Drain Wire
Two or Four Pairs
CM Rated
APPLICATIONS
General Purpose Data
Machine Control
Extended Distance Runs
Mechanical Specifications (Series)
Conductors
Insulation (type, wall thick)/
Color Code
Overall
Shield
Overall
Drain Wire
Jacket
UL
Type
24 AWG (7x32)
Stranded BC
PE, .015"/
See Color Code Chart #3
100% Foil
24 AWG (7x32)
Stranded BC
PVC, Gray
CM
Mechanical Specifications (Individual)
Part #
# of Pairs
Nominal OD
Approx. Wieght
6104
2
.234"
27 lbs/Mft
Low Capacitance Two-pair
6108
4
.277"
43 lbs/Mft
Low Capacitance Four-pair
Electrical Specifications
Capacitance
Cond. DCR
Drain DCR
12.8 pF/ft between conductors,
23.6 pF/ft between one conductor and other tied to shield